當前位置:學者齋 >

IT認證 >H3C認證 >

h3c交換機恢復出廠設定

h3c交換機恢復出廠設定

杭州華三通訊技術有限公司(簡稱華三通訊), 主要提供IT基礎架構產品及方案的研究、開發、生產、銷售及服務。下面是小編整理的關於h3c交換機恢復出廠設定,歡迎大家參考!

h3c交換機恢復出廠設定

  reset saved-configuration

The saved configuration file will be erased. Are you sure? [Y/N]: y // 提示是否擦除配置檔案

Configuration in the device is being cleared.

Please wait ...

...

Configuration in the device is cleared.

reboot

This command will reboot the system. Since the current configuration may have been changed, all changes may be lost if you continue. Continue? [Y/N] Y // 提示是否重啟裝置,按Y將重新啟動

【提示】擦除配置檔案後,必須要重啟裝置後才能恢復到出廠設定。

  H3C交換機檢視光功率收發光命令

[H3C]_hidecmd

Now you enter a hidden command view for developer's testing, some commands may

affect operation by wrong use, please carefully use it with our engineer's

direction.

[H3C-hidecmd]_display transceiver ?

diagnosis Diagnostic information

interface Display by interface

register Register information

[H3C-hidecmd]_display transceiver diagnosis interface GigabitEthernet 1/0/25

GigabitEthernet1/0/25 transceiver diagnostic information:

Current diagnostic parameters:

Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)

54 3.41 17.65 -7.45 -5.85

Alarm thresholds:

Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)

High 85 3.70 65.00 0.97 0.97

Low -10 2.90 10.00 -40.00 -13.01

Parameters when first used on 2000.4.26:

Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)

39 3.41 16.35 -7.21 -5.85

Total account of alarms: 15

Latest occurrence of different alarms:

Type Date Description

Temp N/A N/A

Voltage N/A N/A

Bias N/A N/A

RX power 2014.04.09 RX power low

TX power N/A N/A

TX N/A N/A

RX N/A N/A

OTHER N/A N/A

Latest three alarms:

Date Description

2014.04.07 RX power low

2014.04.09 RX power low

2014.04.09 RX power low

以下是埠沒有插上模組的:

[H3C-hidecmd]display transceiver diagnosis interface GigabitEthernet 1/0/27

Error: The transceiver is absent.

[H3C-hidecmd]display transceiver diagnosis interface GigabitEthernet 1/0/28

Error: The transceiver is absent.

USB是主從模式的,一般意義上,PC被定義為主裝置,提供5V電壓,如果兩邊都是PC,由於供電線需要構成一個本地迴路才能工作,這就可能燒燬主機板,關鍵就是供電迴路問題。我是怎麼做到USB線聯網呢?我是在淘寶上買了一根特殊的USB線,具體怎麼實現的沒有深究,無外乎接地反轉之類的。

USB主從模式的`初衷是為了將外設這類從裝置連線到主機這種龐然大物主裝置上,然而正如你看到的那樣,目前的情況是,龐然大物已經越來越少,桌面PC被使用的越來越少,更多的是同樣大小的小型裝置,手機,平板,....好多年前,乙太網的雙絞線也有本地迴路問題(燒不毀板子,只是脈衝無法傳送和接收,雙絞線沒有單獨的供電線,電壓隨著脈衝發生,因此為了構成迴路,線的一端傳送脈衝,另一端必須接收脈衝),因此那時規定,連線同種裝置需要交叉線,即1-3,2-6線序對調(詳見568A,568B標準),可是後來在PHY層實現了自動協商,不管交叉線還是直連線都可以用於任何支援自協商的網絡卡了。USB的問題在於,你加入了主從的約束,就少了通用性。實際上任何事情,加入一點約束,就會喪失一點通用性。

  • 文章版權屬於文章作者所有,轉載請註明 https://xuezhezhai.com/zh-tw/itrz/h3c/51e1w9.html